Configuring Harmonic Polaris Live: Route

This program works in conjunction with Polaris Play: Ingest and changes the SDI router sources as records take place. Occasionally the settings to this program are lost, or sometimes you may wish to set it up running under a different user.  For reference, the setup for Polaris Live: Route is below:

To reconfigure the router, go to Settings | Configure Routers…

Select the General tab.

  1. Select Add Physical Router
  2. Enter Utah Scientific for the description
  3. Enter 80 for Sources and 80 for Destinations

PLR-RouterConfig

Select the Connection Panel

  1. From the dropdown select Utah Scientific.
  2. In the TCP/IP [Ethernet] section enter 192.168.1.100 for the IP address
  3. For the Port enter 5001 (or click the Default button)
  4. Then click OK.

PLR-Connection

From the main menu select Settings | Configure Clients

Select the Web Panels tab

[x ] Enable Web Panels

Web Server Port [ 8080]

WebSocket Port [81]

Web File Path [ C:\ProgramData\Harmonic\WebPanels

PLR-WebPanels

Once it is up enter 8080 for the Web Server Port.

You should now be able to start the router by clicking the “Run” button from the main dialogue.